Repository logo
 
Publication

Experimental analysis of building air tightness in traditional residential portuguese buildings

dc.contributor.authorSalehi, Atefeh
dc.contributor.authorTorres, Isabel
dc.contributor.authorFerreira, Ana Vaz
dc.date.accessioned2017-07-04T14:04:17Z
dc.date.available2017-07-04T14:04:17Z
dc.date.issued2017
dc.description.abstractIt is currently recognized that the residential building sector is one of the largest energy consumers in the world. The energy crisis of the 1970s was important for drawing attention to the subject of energy consumption and the necessity to save energy. The airtightness of buildings is an important factor affecting a building’s energy consumption and also energy-saving potential. On the other hand, the ventilation rate has also a significant effect on indoor air quality and is assumed to be an essential criterion of a building’s performance. However, most of the existing research in this area has been developed in cold climates and there is a research gap with regard to countries in warmer climates such as those close to the Mediterranean Sea. Therefore, this research aimed to study the airtightness and ventilation rate of existing buildings by employing in-situ measurements. In-situ measurements were achieved using the fan pressurization test (Blower Door Test) method. According to the selected case studies, the results of the measurements indicate a correlation between building typology, airtightness, and ventilation rate.pt_PT
dc.description.versioninfo:eu-repo/semantics/publishedVersionpt_PT
dc.identifier.citationSALEHI, Atefeh, TORRES, Isabel, RAMOS, Ana (2017) - Experimental analysis of building air tightness in traditional residential portuguese buildings. Energy and Buildings. ISSN 0378-7788. Vol. 151, p. 198-210. Doi: 10.1016/j.enbuild.2017.06.037pt_PT
dc.identifier.doi10.1016/j.enbuild.2017.06.037pt_PT
dc.identifier.issn0378-7788
dc.identifier.urihttp://hdl.handle.net/10400.11/5583
dc.language.isoengpt_PT
dc.peerreviewedyespt_PT
dc.publisherElsevierpt_PT
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/pt_PT
dc.subjectNatural ventilationpt_PT
dc.subjectIndoor air qualitypt_PT
dc.subjectAir circulationpt_PT
dc.subjectArchitectural solutionspt_PT
dc.subjectInfiltration ratept_PT
dc.subjectAir permeabilitypt_PT
dc.titleExperimental analysis of building air tightness in traditional residential portuguese buildingspt_PT
dc.typejournal article
dspace.entity.typePublication
oaire.citation.endPage205pt_PT
oaire.citation.startPage198pt_PT
oaire.citation.titleEnergy and Buildingspt_PT
oaire.citation.volume151pt_PT
person.familyNameVaz Ferreira
person.givenNameAna Teresa
person.identifier.ciencia-idFF13-36C3-FA08
person.identifier.orcid0000-0001-7722-2806
rcaap.rightsopenAccesspt_PT
rcaap.typearticlept_PT
relation.isAuthorOfPublicationc8cac0d1-de93-4399-b41f-8990692fd63d
relation.isAuthorOfPublication.latestForDiscoveryc8cac0d1-de93-4399-b41f-8990692fd63d

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Abstract Final ENB.pdf
Size:
23.91 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.02 KB
Format:
Item-specific license agreed upon to submission
Description: