Repository logo
 
Publication

Evacuation of Lisbon’s Baixa-Chiado subway station in case of fire

datacite.subject.fosEngenharia e Tecnologia
dc.contributor.authorBorralho, Tiago
dc.contributor.authorRodrigues, João Paulo
dc.contributor.authorCalmeiro dos Santos, Cristina
dc.date.accessioned2025-02-05T11:48:21Z
dc.date.available2025-02-05T11:48:21Z
dc.date.issued2025-01-03
dc.descriptionAknowledgements: To the Metropolitano de Lisboa for having immediately supported to this work and providing elements that allowed the realization of the present studies. To the Thunderhead Engineering for providing free academic licenses for PyroSim and Pathfinder. To the Laboratory for Advanced Computing of University of Coimbra for enabling the use of its supercomputing resources in some of the numerical simulations.
dc.description.abstractIt is essential to ensure that any building has conditions for a safe evacuation of its occupants. This aspect is essential in subway stations, where evacuation has to be carried out in an upward way, and usually correspond to large structures constituting a single fire compartment. Baixa-Chiado subway station, in Lisbon, Portugal, was selected for studying the evacuation in case of fire, due to its depth, high number of passengers that frequent the station and the existing of two intersecting train lines. A calculation of evacuation time was calculated and the way of evacuation studied, in different fire scenarios, number and location of occupants. The numerical simulations used Fire Dynamics Simulator and Pathfinder softwares, the first for fire spreading and the second for evacuation analysis. The importance of smoke control system, and its rapid activation in case of fire, was highlighted by the results obtained. In situations where this did not occur, there was a significant worsening in the evacuation of the occupants. It was estimated the incapacitation of a significant number of occupants, considering the levels registered for the fractional effective dose. The station’s architectural constraints proved to be a crucial factor in the results of the study. This article highlights important results applicable to subway stations around the world.por
dc.identifier.citationBorralho, T.M.O., RODRIGUES, J.P.C. ; SANTOS, C.C. (2025) - Evacuation of Lisbon’s Baixa-Chiado subway station in case of fire. Archit. Struct. Constr. 5:11. DOI: https://doi.org/10.1007/s44150-025-00127-5
dc.identifier.doi10.1007/s44150-025-00127-5
dc.identifier.urihttp://hdl.handle.net/10400.11/10012
dc.language.isoeng
dc.peerreviewedyes
dc.publisherSpringer Nature
dc.relation.hasversionhttps://link.springer.com/article/10.1007/s44150-025-00127-5#citeas
dc.rights.uriN/A
dc.subjectEvacuation modeling
dc.subjectFire
dc.subjectSubway station
dc.subjectHuman behavior
dc.subjectEmergency
dc.subjectNumerical simulation
dc.titleEvacuation of Lisbon’s Baixa-Chiado subway station in case of firepor
dc.typetext
dspace.entity.typePublication
oaire.citation.endPage12
oaire.citation.startPage1
oaire.citation.titleArchitecture, Structures and Construction
oaire.citation.volume5
oaire.versionhttp://purl.org/coar/version/c_970fb48d4fbd8a85
person.familyNameCalmeiro dos Santos
person.givenNameCristina
person.identifier.ciencia-id0B18-474D-341B
person.identifier.orcid0000-0001-9764-2592
relation.isAuthorOfPublicationb4bf577f-e196-495a-9a6f-28654bdbf947
relation.isAuthorOfPublication.latestForDiscoveryb4bf577f-e196-495a-9a6f-28654bdbf947

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
s44150-025-00127-5.pdf
Size:
1.79 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
2.02 KB
Format:
Item-specific license agreed upon to submission
Description: